| Model : Ei146RC - Optical Smoke Detector |
| Sensor Type : |
Optic |
| Button Test : |
Simulates the effect of smoke. Checks sensor, electronics and sounder. |
| Supply Voltage : |
230V AC, 50Hz |
| Insect Screen : |
Prevents insects or debris entering chamber (1.00mm mesh size). |
| Battery Back-Up : |
9V Alkaline Replaceable. |
| Indicator LEDs : |
Green - Power , Red - Alarm |
| Alarm : |
Electronic Piezo Siren |
| Self Test : |
Ionisation sensor is automatically tested every 40 seconds |
| Sound Level : |
85 dB(A) at 3 metres |
| Memory : |
Red LED will flash twice every 40 seconds indicating recent Alarm event |
| Plastic Material : |
UL94VO flame retardant. |
| Approval : |
BS EN 14604:2005. |
| Interconnection : |
hardwire interconnect up to 12 units. |
| Optional Control : |
- Ei1529RC Control Switch - MCP401RC Manual Call Point |
| Operating Temperature : |
Operating - 0°C to 40°C |
| Storage Temperature : |
Storage - 0°C to 35°C (in a dry area) |
| Product Dimensions : |
150mm dia. x 50mm. |
| Package Dimensions : |
Package - 155mm x 155mm x 55mm. |
| Weight : |
325g (product only), 380g (boxed). |
| Humidity : |
15% to 95% Relative Humidity |