LOREX LR-2100-R12 / LR-2100-R24 Optical Smoke Detector with Relay Output

LOREX LR-2100-R12 and LR-2100-R24 are 4-wire optical smoke detectors with built-in sounder and jumper-selectable NO/NC relay output. They are designed for projects requiring local smoke detection, audible warning and a dry contact alarm signal for control panels, automation inputs, beacons, sirens or shutdown logic.

Overview

The LOREX LR-2100 series is a 4-wire photoelectric smoke detector designed to provide dependable early warning for both fast-flaming and slow smoldering fire scenarios. Its optical smoke chamber is designed to detect smoke particles reliably while maintaining stable detection performance over time.

The LR-2100-R12 version operates with 12V DC and the LR-2100-R24 version operates with 24V DC. Both versions include a built-in sounder and an integrated relay output. The relay can be configured as NO or NC via jumper, making the detector suitable for a wide range of fire alarm, security alarm and automation applications.

Thanks to its relay output, the LR-2100 can send an alarm signal to external systems. This makes it suitable not only for standalone local warning but also for integration with compatible alarm panels, warning beacons, external sirens, access control logic, elevator control, ventilation shutdown or other low-voltage alarm control circuits.

LOREX LR-2100-R12 / LR-2100-R24 Optical Smoke Detector with Relay Output

4-Wire Operation

Designed for installations where separate power and alarm relay wiring are required.

NO/NC Relay Output

Integrated alarm relay can be selected as normally open or normally closed by jumper.

12V / 24V Options

LR-2100-R12 is suitable for 12V DC systems; LR-2100-R24 is suitable for 24V DC systems.

Built-in Sounder

Provides local audible warning with 85 dB sound level at 3 meters.

Key Features

  • Photoelectric optical smoke detection: suitable for early smoke detection in indoor environments.
  • 4-wire smoke detector: ideal for systems requiring dedicated power and relay output wiring.
  • Built-in alarm relay: jumper-selectable NO/NC contact for flexible integration.
  • Built-in sounder: provides local audible warning for immediate response.
  • Two voltage options: LR-2100-R12 for 12V DC and LR-2100-R24 for 24V DC installations.
  • LED status indication: clear indication for alarm and operating status.
  • Ceiling mount design: base included for practical installation.
  • External device control: relay output can trigger compatible panels, beacons, sirens or automation inputs.

Applications

With optical smoke detection, built-in sounder and an integrated NO/NC relay output, the LR-2100 series is suitable for:

  • Residential buildings, apartments and villas
  • Offices and commercial spaces
  • Hotels, guest rooms and hospitality areas
  • Retail stores and shopping areas
  • Warehouses and storage facilities
  • Manufacturing and light industrial environments
  • Educational and healthcare facilities
  • Automation projects requiring smoke alarm relay contact
  • Warning beacon, siren or local alarm integration

Relay Output Usage

The integrated relay output is one of the most useful features of the LOREX LR-2100-R12 / LR-2100-R24. In alarm condition, the relay can provide a contact signal to compatible external equipment. Depending on the project design, this contact can be used for:

  • Sending alarm information to a burglar alarm or fire alarm control panel
  • Activating a warning beacon or external sounder
  • Triggering a low-voltage automation input
  • Starting local alarm logic in a small control system
  • Providing smoke alarm status to a monitoring circuit

The relay contact must always be wired according to the electrical limits of the product and the requirements of the connected equipment.

Technical Specification

Price: On Request  |  Availability: In Stock

Parameter LR-2100-R12 LR-2100-R24
Order Code LR-2100-R12 LR-2100-R24
Detector Type Photoelectric / Optical Smoke Detector
Operation 4-wire
Supply Voltage 12V DC 24V DC
Alarm Current 20 mA 10 mA
Relay Output NO or NC, jumper selection
Relay Contact Rating 1A @ 24V
Internal Sounder Yes
Sounder Level 85 dB @ 3m
LED Indicator Yes
Mounting Type Ceiling Mount, Base Included
Color White
Case ABS Plastic
Working Temperature 0°C ~ 40°C
Dimensions 13 cm x 3.7 cm
Humidity 10% ~ 90% RH

For integration projects, relay logic, smoke detector wiring or system selection support, please contact our sales team.

Wiring Diagram

LOREX LR-2100-R12 / LR-2100-R24 Wiring Diagram

LOREX LR-2100-R12-R24 Smoke Detector with Relay Output Wiring Diagram

LOREX LR-2100-R12-R24 Smoke Detector with Relay Output Wiring Diagram

Frequently Asked Questions

What is the difference between LR-2100-R12 and LR-2100-R24?

LR-2100-R12 operates with 12V DC, while LR-2100-R24 operates with 24V DC. Both models are 4-wire optical smoke detectors with built-in sounder and NO/NC relay output.

Does the LOREX LR-2100 have a relay output?

Yes. The LOREX LR-2100-R12 and LR-2100-R24 include an integrated alarm relay output. The relay contact can be selected as NO or NC by jumper.

Where can this relay smoke detector be used?

It can be used in residential buildings, offices, hotels, retail areas, warehouses, light industrial environments and other locations where a 12V or 24V 4-wire smoke detector with relay output is required.

Can the relay output trigger external devices?

Yes. The NO/NC relay output can be used to send an alarm signal to compatible control panels, warning beacons, sirens, automation inputs or shutdown logic, depending on the project wiring.

WhatsApp Contact