| Main Page > Fire Alarm Systems > Gas Detectors > E2638 SF6 Gas Leak Monitor Transmitter , SF6 Gas Detector |
| |
 |
| E2638 SF6 Gas Leak Monitor Transmitter , SF6 Gas Detector |
|
|
|
-
Sulfur hexafluoride detector-transmitter E2638-SF6 is a member of PluraSens® family of multifunctional measurement instruments.
-
E2638-SF6 Gas Detector is specifically designed to monitor and early warning against SF6 leakage at power plants , transformers in high voltage engineering .
The instrument utilises a fully calibrated and temperature compensated optical NDIR gas sensor with excellent repeatability, stability and long lifetime.
Two relays with closing contact (optional) may be used for remote signalling or concentration control. Two alarm set-points are user settable.
Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.
- General Feature
- Stable long-life optical NDIR sensor
- Range 0...1000 or 2000 ppm SF6
- Resolution 2 ppm or 4 ppm SF6
- Two SPST relays (option)
- 2 × 4-20 mA or 0-10 V, RS485
|
| |
|
| Price : On Request |
|
| |
| What is SF6 Gas Transmitter Used for ? |
|
Although sulphur hexafluoride is non-toxic and non-flammable, its global warming potential is about 24,000 times higher than carbon dioxide (GWP=23,900). That makes it the most potent of all greenhouse gases, which is why its use is subject to the most stringent environmental regulations. In addition, sulphur hexafluoride is odourless and heavier than air, so that it can accumulate in case of SF6 leaks in low-lying areas of the gas-insulated switchgear. Without reliable SF6 monitoring with SF6 gas sensors there would be a danger of asphyxiation for the workers.
|
| |
| |
| Technical Specifications |
|
| Order Code : LR-E2638-SF6 - SF6 Gas Detector |
| Calibration : : |
Sulfur Hexafluoride SF6 |
| Sensor Type : |
dual beam NDIR |
| Sampling Method : |
Diffusion |
| Typical detection ranges : |
0...1000ppm - 0....2000ppm |
| Resolutions: |
0.2% FS |
| Response T90 Time : |
< 30 s |
| Sensor MTBF : |
> 5 years |
| Maintenance interval : |
1 year |
| Signal Update : |
every 1 second |
| Self-diagnostics : |
Full functionality check at start-up |
| Warm-up Time : |
≤ 1 min |
| Power Supply Options : |
11...30 VDC, 24 VAC or 90...265 VAC |
| Power Consumptions : |
< 2 VA |
| Digital Interface : |
RS485, Modbus RTU protocol |
| Analog Outputs : |
2 × 4-20 mA / 0-10 V, user settable |
| Output Scale Width |
recommended: 20-100% of the range; > 10 × resolution in any case |
| Eclosure : |
grey ABS plastic, wall mount, protection class IP65 |
| Dimensions : |
H90 × W145 × D50 mm (housing only) H140 with cable glands |
| Operating Environment : |
ndustrial indoor and outdoor locations |
| Operating Conditions : |
20...+50 °C; 15...90% RH non-condensing;
0,9...1,1 atm; explosion safe areas non-aggressive atmosphere
NOTE We offer technical solutions for extreme
humidity, please ask for more information
|
|
| |