About Us | Career | +90 212 483 17 83 | Contact

 

Main Page > Fire Alarm Systems > Crowcon Xgard Fixed Gas Detectors

 

Crowcon Xgard Fixed Gas Detectors

 
  • The Crowcon Xgard Range is a comprehensive selection of fixed point gas detectors that meet the diverse requirements for gas detection in industries throughout the world. This includes many water treatment, oil and gas, power, research facility and manufacturing installations.
  • Intrinsically Safe (I.S.) or Flameproof (Exd) versions are available, with case options comprising high-grade alloy, stainless steel or chemically resistant GRN polymer. Certifications include IECEx, ATEX, UL and GOST-R.
  • Designed for easy installation and maintenance – keeps costs down
  • Three junction box options – designed to make replacement of sensors and sinters extremely simple. Spare sensors simply plug-in
  • Many spare parts are common to all Xgard models – keeps spares holding requirements to a minimum

 


Price : On Request

 
  • Designed for either wall or ceiling mounting – no need for additional brackets
  • Can accommodate M20, 1/2″ NPT or 3/4″ NPT cable glands – suits all site requirements
  • High temperature models are available for hot environments (up to 150oc)
  • Accessories are available for duct mounting and sampling applications as well as remote gassing – simple sensor checking
Wide Range of Sensors
  • Poison resistant pellistors, for all flammable detection needs including hydrocarbons, hydrogen, ammonia, jet fuel, leaded petrol and vapours containing halogens
  • Electrochemical sensors are used to detect a vast range of toxic gases and oxygen
  • Thermal conductivity sensors are available to monitor % volume concentrations of gases
Rugged and Reliable
  • Manufactured using a choice of three materials: glass reinforced nylon, highly durable aluminium with a tough polyester coating, or 316 stainless steel for ultimate corrosion resistance – designed to operate even in the harshest environments
  • Spray deflectors and weatherproof caps are available for use in areas subject to regular wash-downs, or offshore environments
  • All models have been validated to the functional safety standard IEC 61508 (SIL 1 to SIL 3)
Click the link for choosing correct type of Xgard Detector
 
Technical Specification
 
TYPE1
TYPE2
TYPE3
TYPE4
TYPE5
TYPE6
Size
156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches)
195 x 166 x 111mm (7.6 x 6.5 x 4.3 inches)
156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches)
Weight
Nylon: 0.5 kgAlloy: 1kg (2.2lbs)316 S/S: 3.1kg (6.8lbs)
Aluminium: 1kg (2.2lbs)Stainless steel: 3.1kg (6.8lbs)
1.5 kg (3.3lbs)
Aluminium: 1kg (2.2lbs) Stainless steel: 3.1kg (6.8lbs)
Enclosure Material
ATEX certified: Glass reinforced nylon or 316 S/SUL Certified: Aluminium or 316 S/S
Aluminium or 316 Stainless Steel
Aluminium
Aluminium or 316 Stainless Steel
Ingress Protection
IP65
IP54
IP65
Cable Entries
1 x M20, 1/2 “NPT or 3/4 NPT* on right-side
Terminations
0.5 to 2.5mm2
Sensor Type
Electrochemical
Catalytic bead 316 S/S sensor housing with catalytic beads Catalytic bead Thermal conductiv
Operating temperature
-40 to +50 °C
(-40 to 122 °F)
(sensor dependant)
-20 to +50°C (-4 to 122°F)
-40 to +80°C
(-40 to 176°F)
-20 to +150°C (-4 to 302°F)
-40 to +55°C (-40 to 131°F)
+10 to +55°C (50 to 301°F)
Humidity
10 to 95% RH non-condensing0-99% RH non-condensing
0-99% RH non-condensing
0-90% RH
Repeatability Zero drift
<2% FSD (Typical)<2% FSD per Month (Typical)
Response time
T90 <15s OxygenT90 <30s to 120s Toxic(sensor dependant)
T90 <15s (Typical)
Operating voltage
8-30V dc
2.0V dc +/- 0.1V (Typical)
10-30V dc
Power requirements
24mA maximum
300mA (Typical)
50mA at 24V dc 1.2W
Electrical output
2- wire 4-20mA (current sink)
3- wire mV bridgeTypical signal: 12-15mV/ %LEL CH4
3- wire mV bridgeTypical signal: >10mV/%LEL CH4
3- wire 4-20mA (current sink or source)
Approvals
ATEX: II 1 G
Exia IIC T4 Ga
(Tamb -40 to +55°C)
UL/cUL: Class I, Div. 1
Groups A, B, C, D
IECEx
EAC
ATEX: II 2GD
Exd IIC T6 Gb (Tamb -40 to +50°C)
UL: Class I, Div. 1
Groups B, C, D
IECEx
EAC
ATEX: II 2 GD
Exd IIC T4 Gb
(Tamb -40 to +80°C)
Exd IIC T6 Gb (Tamb -40 to +50°C)
Ex tb IIIC
T180°C Db
UL: Class I, Div. 1
Groups B, C, D
IECEx
EAC
ATEX: II 2 GDExd IIC T3 Gb (Tamb -40 to +150°C)
ATEX: II 2 GDExd IIC T6 Gb (Tamb -40 to +50°C)
Exd IIC T4 Gb (Tamb -40 to +80°C)
Ex tb IIIC
T180°C Db
UL: Class I, Div. 1
Groups B, C, D
IECEx
EAC
EMC compliance
EN 50270       FCC Part 15    ICES- 003
 
FURKAN ENGINEERING 2021
www.furkanmuhendislik.com.tr | info@furkanmuhendislik.com.tr