English
Türkçe
Furkan Engineering had been running for the world's security since 1992 
 

 

Main Page > Fire Alarm Systems > Gas Detectors > LOREX Portable Gas Detector > Portable Single Gas Detector > GAS-BI-A-001-G Portable Carbonmonoxide Gas Detector

 

GAS-BI-A-001-G Portable Carbon Monoxide Gas Detector (0-1500ppm)

 

Furkan Engineering offers small, light and easy to use portable carbon monoxide gas detectors . It has 0-1500ppm measuring range. Weighing just 130g , it is extremely durable, with high impact resistance and dust/water ingress protection to IP65. When potentially hazardous levels of gas are detected , portable gas detectors alerts the user with a loud 95 dB alarm, a vivid red / blue visual warning and also by vibrating.

General Features

Electrochemical Carbon Monoxide Gas Sensor
Rechargable Battery
12 Hours Minimum Operating Time for Re-chargable Battery Versions
Water and dust resistant to IP65
ATEX and CSA Certificate
Vivid RED / BLUE Visual Warning
95 dB Audible Alarm + Vibrating alarm
Full timed datalogging with adjustable sample rate, set to 1 min. data rate as default.
900 hours storage at 1 min. interval (54,000 logs), >4800 events


 
 
Technical Specifications

Order Code , Description :
GAS-BI-A-001-G Portable Carbonmonoxide Gas Deector (0-1500ppm)
Measuring Range : 0-1500ppm
PC Interface : RS232
Operation standards : EN50270, EN50271, IEC61508, EN61779, EN45544
Standards Safety :
EN60079-0, EN60079-11, EN60079-1, 94/9/EC
ATEX :
ATEX II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +65OC) BASEEFA04ATEX0384
Operating Time :
12 hours minimum for flammable unit
Battery :
Lithium battery for all gas types
Data Logging :
Full timed datalogging with adjustable sample rate, set to 1 min. data rate as default.
900 hours storage at 1 min. interval (54,000 logs), >4800 events
Display :
Custom LCD with backlight, with display of gas concentration. Graphic symbols for battery (with proportional indication of remaining operation time), and display mode. Start up indication when calibration is due within 30 days , calibration overdue or service required.
Visible Alarm : Dual colours red/ blue flashing LEDs in a gas hazard
Audible Alarm : 95dB Multiple alarm options let you select distinctive tones for different alarm levels
Vibrating Alarm :
Internal vibrating alarm
Typical response times (T90)
10s
Weight :
129g (4.6oz)
Operating Temperature : -20o C to + 65o C (-4o F to +149o F)
Dimensions :
90 x 48 x 24 mm (3.5 x 1.9 x 0.95 ins)
 
Other Products We Recommend