CFP-708-4 8 Zone Conventional Fire Alarm Control Panel
Overview
Certified to EN54 parts 2, 4 and 13, the C-TEC CFP708-4 Standard 8 Zone Conventional Fire Alarm Control Panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure, it includes eight detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays, and combined keypad/keyswitch entry.
A wide range of engineering functions are also provided, including selectable zone delays, coincidence programming and non-latching zone facilities. Comprehensive test and fault-finding functions help simplify commissioning, servicing and long-term system maintenance.
Optional repeaters and relay expansion boards are available, making the CFP708-4 a flexible choice for conventional fire alarm applications where clear indication, ease of use and dependable EN54-certified performance are essential.
Key Features & Benefits
Third-Party Certified Compliance
Certified to EN54-2 and EN54-4 by the LPCB and to EN54-13 by Kiwa Telefication, offering dependable compliance for conventional fire alarm applications.
User-Friendly Interface
The panel features an intuitive, user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry for simple day-to-day operation and controlled engineering access.
Installer-Friendly Design
Designed for efficient installation, the CFP708-4 is supplied in an attractive plastic lid and enclosure suitable for flush or surface mounting, with no bezel required.
Flexible Engineering Functions
Selectable zone delays, coincidence operation, zone test and non-latching zone setup provide useful flexibility for system design, testing and commissioning.
Expansion Capability
System expansion connections are provided for up to eight two-wire repeaters, optional relay output boards and optional EN54-13 compliant sounder circuit boards.
ActiV Device Compatibility
Fully compatible with C-TEC’s ActiV fire detectors, sounders and visual alarm devices for dependable system integration.
More Information
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) and EN54 part 13 certified by Kiwa Telefication.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Eight detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays: Fire and Fault.
- Two open-collector outputs: Remote and Reset.
- Class change and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure with no bezel required.
- Low 25mA quiescent current.
- Multiple status indicators.
- System expansion connections for repeaters, relay boards and EN54-13 compliant sounder circuit boards.
- Space for two 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV fire detectors, sounders and visual alarm devices.
Engineering Functions
Coincidence (Double Knock)
Supports programmable coincidence logic to help reduce unwanted alarms by requiring a defined alarm sequence before full activation.
One Man Walk Test
Provides an efficient walk test mode that helps simplify commissioning and routine testing by a single engineer.
Zone Delay
Selectable delays can be configured to match application requirements and cause-and-effect strategies.
Non-Latching Zones
Zones can be set for non-latching operation where reset behaviour must follow a specific site requirement.
Sounder Resound Programming
Engineers can program sounders to resound or not resound after silence, depending on the desired operating logic.
Test & Fault Finding Tools
Comprehensive test and fault-finding facilities help reduce maintenance time and support fast diagnostics.
The CFP708-4 is housed in an attractive flush or surface mountable plastic enclosure and does not require a bezel.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product | C-TEC CFP Standard 8 Zone Conventional Fire Alarm Panel |
| Part Number | CFP708-4 |
| Approvals / Certifications | Certified to EN54-2 & 4 by the LPCB; Certified to EN54-13 by Kiwa Telefication |
| Mains Supply | 230V 50/60Hz |
| Mains Rated Current | 350mA maximum |
| Internal Power Supply | 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault) |
| Total Output Current Limited To | 1.5A @ 230Vac (ImaxA eq 146mA) |
| Quiescent Current | 25mA (mains failed, internal sounder active, PSU & general fault LED lit) |
| Max Battery Size and Type | 2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah |
| Number of Detector Zone Circuits | 8 (maximum length per circuit is 500m) |
| Call Point Resistor Value | 470 to 680Ω |
| Max Devices per Detector Zone | 25 detectors (or 32 detectors/manual call points combined) |
| Number of Conventional Sounder Circuits | 4 (maximum length per circuit is 500m) |
| EOL Resistor Value | 6800Ω 5% Tol. 0.25W (blue, grey, red, gold) |
| Alarm Voltage | 27V max, 20V min (final battery voltage) |
| Max Sounder Output Current | 4 x 200mA (800mA total) |
| Auxiliary Relays | Two: (1) Aux. Fire; (2) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc |
| Open Collector Outputs | Two: (1) Reset (active during reset cycle); (2) Remote (active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA; Max. open circuit voltage 30Vdc |
| Other Outputs | 24V Aux. Power (protected by a resettable fuse. 100mA minimum hold current. Resets when fault removed) |
| Auxiliary Inputs | Two: (1) Class Change (constant sounders); (2) Alert (pulsed sounders). Connect to 0V to trigger, max. input voltage 27V (non-latching) |
| Engineer (AL3) Functions | Program coincidence (double knock); invoke One Man Walk Test; program delays; set up zones for non-latching operation; program sounders to resound (or not resound) |
| Expansion Connections | Yes – for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards |
| Product Dimensions | 380 W x 235 H x 96 D mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required) |
| Construction & Finish | Plastic lid and base; RAL7035 textured |
| IP Rating | IP30 |
| Weight | 1.75kg (without batteries) |
| Operating Conditions / Temperature | -5°C to +40°C. Max relative humidity: 95% |
Why Choose the CFP708-4?
The CFP708-4 combines EN54-certified performance, practical engineering flexibility and straightforward operation in a compact conventional fire alarm control panel. With eight detector zones, four sounder circuits, low quiescent current and a built-in 1.5A power supply, it offers a dependable solution for a broad range of conventional fire alarm installations.
For installers, it provides simple commissioning, comprehensive diagnostics and useful expansion options. For end users, it delivers clear indication and intuitive controls. For system designers, it offers compatibility with a wide range of C-TEC conventional detection and notification products within the CFP platform.