CFP-704-4 4 Zone Conventional Fire Alarm Control Panel
Overview
Certified to EN54 parts 2, 4 and 13, the C-TEC CFP704-4 Standard 4 Zone Conventional Fire Alarm Control Panel offers an array of user and installer-friendly features at a very competitive price. Housed in an attractive plastic enclosure suitable for flush or surface mounting, it provides four detector zone circuits, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays, and combined keypad/keyswitch entry.
A wide range of engineering functions are included to support flexible system design and commissioning. These include selectable zone delays, coincidence programming, non-latching zone facilities, and practical test and fault-finding tools for efficient setup and maintenance.
Optional repeaters and relay expansion boards are also available, allowing the panel to be adapted for broader conventional fire alarm applications while maintaining a straightforward and installer-friendly operating platform.
Key Features & Benefits
Third-Party Certified Compliance
Certified to EN54-2 and EN54-4 by the LPCB and to EN54-13 by Kiwa Telefication, providing confidence in performance, compatibility and fire system integrity.
User-Friendly Interface
An intuitive front panel with colour-coded buttons and combined keypad/keyswitch entry makes everyday operation simple for users while still providing controlled access for engineers.
Installer-Friendly Design
The CFP704-4 has been designed to ease installation and maintenance, featuring practical test and fault-finding functions and a neat flush or surface mountable enclosure that requires no bezel.
Flexible Engineering Functions
Advanced features such as zone test, coincidence, zone delay, non-latching zones and sounder resound programming allow the panel to be adapted to a wide range of applications.
Expansion Capability
System expansion connections are provided for up to eight two-wire repeaters, optional relay output boards and optional EN54-13 compliant sounder circuit boards.
ActiV Device Compatibility
Fully compatible with C-TEC’s ActiV fire detectors, sounders and visual alarm devices for reliable conventional fire alarm system integration.
More Information
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) and EN54 part 13 certified by Kiwa Telefication.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays: Fire and Fault.
- Two open-collector outputs: Remote and Reset.
- Class change and alert inputs.
- Low 25mA quiescent current.
- Multiple status indicators for clear visual monitoring.
- System expansion connections for repeaters, relay boards and sounder circuit interface boards.
- Space for two 12V VRLA batteries.
- Fully compatible with C-TEC’s ActiV fire detectors, sounders and visual alarm devices.
Engineering Functions
Coincidence (Double Knock)
Allows programmable coincidence logic to help reduce unwanted alarms by requiring a defined alarm sequence before full activation.
One Man Walk Test
Provides a practical test mode to simplify commissioning and ongoing maintenance checks by a single engineer.
Zone Delay
Selectable zone delays can be configured to suit site-specific cause and effect requirements.
Non-Latching Zones
Zones can be set for non-latching operation when the application requires automatic reset behaviour.
Sounder Resound Programming
Sounders can be programmed to resound or not resound after silence, depending on the chosen operating strategy.
Comprehensive Fault Finding
Integrated diagnostic and test functions help reduce maintenance time and support fast fault identification.
The CFP704-4 is supplied in an attractive plastic lid and base enclosure suitable for flush or surface mounting, with no bezel required.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product | C-TEC CFP Standard 4 Zone Conventional Fire Alarm Panel |
| Part Number | CFP704-4 |
| Approvals / Certifications | Certified to EN54-2 & 4 by the LPCB; Certified to EN54-13 by Kiwa Telefication |
| Mains Supply | 230V 50/60Hz |
| Mains Rated Current | 350mA maximum |
| Internal Power Supply | 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault) |
| Total Output Current Limited To | 1.5A @ 230Vac (ImaxA eq 146mA) |
| Quiescent Current | 25mA (mains failed, internal sounder active, PSU & general fault LED lit) |
| Max Battery Size and Type | 2 x 12V 3.2Ah VRLA connected in series. Minimum battery size 1.2Ah |
| Number of Detector Zone Circuits | 4 (maximum length per circuit is 500m) |
| Call Point Resistor Value | 470 to 680Ω |
| Max Devices per Detector Zone | 25 detectors (or 32 detectors/manual call points combined) |
| Number of Conventional Sounder Circuits | 4 (maximum length per circuit is 500m) |
| EOL Resistor Value | 6800Ω 5% Tol. 0.25W (blue, grey, red, gold) |
| Alarm Voltage | 27V max, 20V min (final battery voltage) |
| Max Sounder Output Current | 4 x 200mA (800mA total) |
| Auxiliary Relays | Two: (1) Aux. Fire; (2) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc |
| Open Collector Outputs | Two: (1) Reset (active during reset cycle); (2) Remote (active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA |
| Other Outputs | 24V Aux. Power (protected by a resettable fuse, 100mA minimum hold current, resets when fault removed) |
| Auxiliary Inputs | Two: (1) Class Change (constant sounders); (2) Alert (pulsed sounders). Connect to 0V to trigger, max input voltage 27V, non-latching |
| Engineer (AL3) Functions | Program coincidence (double knock); invoke One Man Walk Test; program delays; set up zones for non-latching operation; program sounders to resound (or not resound) |
| Expansion Connections | Yes – for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards |
| Product Dimensions | 380 W x 235 H x 96 D mm (hole required for flush mounting = 367 W x 220 H x 75 D mm) |
| Construction & Finish | Plastic lid and base; RAL7035 textured |
| IP Rating | IP30 |
| Weight | 1.75kg (without batteries) |
| Operating Conditions / Temperature | -5°C to +40°C. Maximum relative humidity: 95% |
Why Choose the CFP704-4?
The CFP704-4 combines EN54 compliance, straightforward operation and practical engineering flexibility in one compact conventional fire alarm control panel. With four detector zones, four sounder circuits, low quiescent current and a built-in 1.5A power supply, it offers a dependable solution for a wide range of small to medium-sized fire alarm installations.
For installers, it offers easy commissioning, comprehensive diagnostics and expansion options. For end users, it provides clear indication and intuitive controls. For system designers, it offers compatibility with a broad range of C-TEC conventional detection and notification devices within the established CFP platform.