CFP-702-4 2 Zone Conventional Fire Alarm Control Panel
Overview
Certified to EN54 parts 2, 4 and 13, C-TEC’s CFP702-4 Standard 2 Zone Conventional Fire Alarm Panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.
A wide range of engineering functions are provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also included, making the panel suitable for a broad range of conventional fire alarm system applications.
Optional repeaters and relay expansion boards are also available, allowing the panel to be adapted to more demanding site requirements while maintaining a straightforward, installer-friendly platform.
Key Features & Benefits
Third-party Certified Performance
Certified to EN54-2 and EN54-4 by the LPCB and to EN54-13 by Kiwa Telefication, giving confidence in compliance, compatibility and overall system integrity.
User-Friendly Interface
Intuitive colour-coded buttons and combined keypad/keyswitch entry make everyday operation simple for end users while retaining installer-level access when needed.
Installer-Friendly Design
Designed to simplify installation and commissioning, with comprehensive test and fault-finding facilities and an attractive flush or surface mountable plastic enclosure that requires no bezel.
Flexible Engineering Functions
Provides advanced features such as zone test, coincidence, zone delay, non-latching zone configuration and programmable sounder resound behaviour.
Expansion Capability
Expansion connections are provided for up to eight two-wire repeaters using a CFP761 network card, plus optional relay output cards and EN54-13 sounder circuit interface boards.
Full ActiV System Compatibility
Fully compatible with C-TEC’s ActiV fire detectors, sounders and visual alarm devices, supporting reliable conventional fire alarm system design.
More Information
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) and EN54 part 13 certified by Kiwa Telefication.
- Manufactured by C-TEC in the UK.
- Two detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays: Fire and Fault.
- Two open-collector outputs: Remote and Reset.
- 'Class change' and alert inputs.
- Low 25mA quiescent current.
- Multiple indicators for clear status visibility.
- Space for two 12V 3.2Ah/3.3Ah VRLA batteries connected in series.
Engineering Functions
Coincidence (Double Knock)
Allows coincidence programming to help reduce unwanted alarms by requiring specific alarm criteria before full system activation.
One Man Walk Test
Provides a practical commissioning and maintenance aid for checking zones and field devices efficiently.
Zone Delay
Selectable zone delays can be configured to suit site-specific cause-and-effect requirements.
Non-Latching Zones
Zones can be set up for non-latching operation where the application requires this type of response.
Sounder Resound Programming
Sounders can be programmed to resound or not resound depending on the selected operational strategy.
Fault Finding Facilities
Comprehensive test and diagnostic functions help simplify servicing and reduce maintenance time.
The CFP702-4 is supplied in an attractive plastic lid and base enclosure suitable for either flush or surface mounting, with no bezel required.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product | C-TEC CFP Standard 2 Zone Conventional Fire Alarm Panel |
| Part Number | CFP702-4 |
| Approvals / Certifications | Certified to EN54-2 & 4 by the LPCB; Certified to EN54-13 by Kiwa Telefication |
| Mains Supply | 230V 50/60Hz |
| Mains Rated Current | 350mA maximum |
| Internal Power Supply | 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault) |
| Total Output Current Limited To | 1.5A @ 230Vac (ImaxA eq 146mA) |
| Quiescent Current | 25mA (mains failed, internal sounder active, PSU & gen fault LED lit) |
| Max Battery Size and Type | 2 x 12V 3.2Ah VRLA connected in series. Minimum battery size 1.2Ah |
| Number of Detector Zone Circuits | 2 (maximum length per circuit is 500m) |
| Call Point Resistor Value | 470 to 680Ω |
| Max Devices per Detector Zone | 25 detectors (or 32 detectors/manual call points combined) |
| Number of Conventional Sounder Circuits | 4 (maximum length per circuit is 500m) |
| EOL Resistor Value | 6800Ω 5% Tol. 0.25W (blue, grey, red, gold) |
| Alarm Voltage | 27V max, 20V min (final battery voltage) |
| Max Sounder Output Current | 4 x 200mA (800mA total) |
| Auxiliary Relays | Two: (1) Aux. Fire; (2) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc |
| Open Collector Outputs | Two: (1) Reset (active during reset cycle); (2) Remote (active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA |
| Other Outputs | 24V Aux. Power (protected by a resettable fuse, 100mA minimum hold current, resets when fault removed) |
| Auxiliary Inputs | Two: (1) Class Change (constant sounders); (2) Alert (pulsed sounders). Connect to 0V to trigger, max input voltage 27V, non-latching |
| Engineer (AL3) Functions | Program coincidence (double knock); invoke One Man Walk Test; program delays; set up zones for non-latching operation; program sounders to resound (or not resound) |
| Expansion Connections | Yes – for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards |
| Product Dimensions | 380 W x 235 H x 96 D mm (flush mounting hole required = 367 W x 220 H x 75 D mm) |
| Construction & Finish | Plastic lid and base; RAL7035 textured |
| IP Rating | IP30 |
| Weight | 1.75kg (without batteries) |
| Operating Conditions / Temperature | -5°C to +40°C. Maximum relative humidity: 95% |
Why Choose the CFP702-4?
The CFP702-4 brings together EN54 compliance, practical engineering flexibility and a user-friendly operating interface in one compact conventional fire alarm panel. With two detector zones, four sounder circuits, low quiescent current and a built-in 1.5A power supply, it provides a dependable solution for many small to medium-sized fire alarm system projects.
For installers, it offers straightforward commissioning and diagnostics. For end users, it provides clear controls and indication. For system designers, it offers expansion possibilities through repeaters, relay boards and interface options, all within the established C-TEC CFP platform.