RGB Technology ZA5-L 4 Digit Outdoor Wall Clock
The ZA5-L PrestigeLine outdoor clock features a durable polycarbonate housing engineered for high mechanical strength and resistance to UV radiation. Thanks to its thermo-moulded enclosure design and rear sealing layer, the device—when properly assembled—meets the IP66 tightness requirements, making it a reliable choice for outdoor installations.
The ZA5-L offers a clear 4-digit, 7-segment red LED display with a 50 mm digit height, providing excellent readability. It supports modern network-based management via LAN / WWW and can be powered through PoE (IEEE 802.3af) / PoE+ (IEEE 802.3at) for flexible deployment.
In addition to displaying time in HH:MM format, ZA series clocks can be configured with advanced functions such as stopwatch operation, optional relay output and automatic brightness control. For larger viewing distances, digit height options are available in 5, 10, 15 and 20 cm (ZA version: 4 digits).
Key Features
- Outdoor-ready design: PrestigeLine polycarbonate housing with IP66 tightness (when properly assembled).
- High visibility display: 4-digit, 7-segment red LED with 50 mm (5 cm) digit height.
- LAN / WWW control: Built-in web panel for fast configuration and remote management.
- PoE / PoE+ power: IEEE 802.3af and IEEE 802.3at support for simplified installations.
- Automatic brightness control: Sensor-based brightness adjustment for outdoor light conditions.
- Stopwatch function: Suitable for timing and operational use cases.
- Optional relay output: Enables external signaling or integration scenarios.
- Digit size options: Available digit heights: 5, 10, 15 and 20 cm (ZA version: 4 digits).
Settings Management (WEB Panel)
Every LAN-enabled device includes a built-in WEB PANEL that is accessible through the network using a standard internet browser. Management can be performed from a PC, tablet, smartphone or any device with a web browser, allowing fast access to key parameters without additional software.
Advantages of the solution include embedded functionality, a clear and tabular overview of settings, the ability to manage multiple clocks from one location via the network and remote management through the internet from virtually anywhere.
Time Synchronization & Clock Systems
Time in ZA/ZB series clocks can be set manually or via automatic time synchronization using two main options: GPS time synchronization and NTP (Network Time Protocol) time server client operation. This makes the ZA5-L suitable for synchronized clock systems in workplaces, schools, stations, platforms and other critical environments.
1) GPS Time Synchronization
GPS signals include highly accurate time and date information derived from atomic standards. For proper operation, the GPS receiver should be installed in a location with clear sky visibility. To use satellite time synchronization, equip the clock with the optional GPS Receiver.
Advantages: precise synchronization from satellites, no internet required, minimal configuration, global operation, and receiver LED indication for signal reception.
2) NTP Time Server Client
NTP (Network Time Protocol) supports precise, stable and safe synchronization with time servers over the network. A key advantage is synchronizing many devices simultaneously. Synchronization can be performed from a local time server (no internet required) or public time servers (internet required). The NTP synchronization is carried out via Ethernet, which is included as standard.
Benefits: reliable operation using multiple time servers (1 primary + 4 alternative), automatic failover between servers if a failure is detected and consistent time across multiple clocks in the system.
Local NTP Time Server Function
Every clock in the ZA/ZB series can operate as a central clock (MASTER) providing the time source to other clocks (SLAVE) over the LAN. This enables easy implementation of a synchronized clock system where the master clock can receive time from GPS, a public NTP server or its own internal clock.
Providing synchronized time to all clocks ensures everyone uses the same time reference—especially important for production halls, schools, stations, platforms, airports, logistics centers and similar environments.
Applications
- Indoor: production halls, receptions, swimming pools, workplaces, corridors, waiting rooms, schools
- Outdoor: building entrances (prestige facade element), open sports facilities
- Transport & infrastructure: stations, platforms, airports, passenger information, logistics centers
- Vehicles: public transport vehicles
- Signage: pylons, welcome signs and advertising totems
Technical Specifications
| Item | Value |
|---|---|
| Product | RGB Technology ZA5-L 4 Digit Outdoor Wall Clock |
| Display | 4-Digit, 7-Segment Red LED |
| Display Format | Time: Hours, Minutes (HH:MM) |
| Digit Height | 50 mm (5 cm) |
| Control | LAN / WWW (Web Panel) |
| IP Rating | IP66 |
| Mounting | Keyhole cut-outs for surface mounting |
| Power | IEEE 802.3af (PoE), IEEE 802.3at (PoE+) |
| Operating Temperature | -25°C to +45°C / -13°F to +113°F |
| Storage Temperature | -25°C to +60°C / -13°F to +140°F |
| Storage Humidity | < 99% RH |
| Dimensions | 141 mm x 298 mm x 42 mm |
| Weight | 1 kg |
| Power Consumption | 10 W |
Installation Notes & Frequently Asked Questions
Installation & Network Setup Notes
- For outdoor installations, ensure the clock is mounted on a stable surface and the viewing angle is optimized for readability.
- When using PoE / PoE+, verify switch power budget and cable quality; consider voltage drop and network best practices.
- For IP66 performance, follow the official assembly and sealing instructions and avoid improper cable entry practices.
- Use the WEB PANEL for centralized configuration; document IP addressing and time sources (GPS/NTP) for maintenance.
- In multi-clock systems, define one device as MASTER time source and configure the others as SLAVE where applicable.
FAQ – Frequently Asked Questions
-
Is ZA5-L suitable for outdoor environments?Yes. The PrestigeLine polycarbonate housing is designed for outdoor use and can meet IP66 tightness requirements when properly assembled.
-
How can I configure the clock?ZA5-L includes a built-in web panel (LAN/WWW) accessible from a browser on PC, tablet or smartphone.
-
How does time synchronization work?You can synchronize via GPS (optional receiver) or via NTP over Ethernet. NTP supports multiple time servers and automatic failover.
-
Can it be powered with PoE?Yes. It supports IEEE 802.3af (PoE) and IEEE 802.3at (PoE+).
-
Are other digit sizes available?Yes. Available digit heights include 5, 10, 15 and 20 cm (ZA version: 4 digits).