E2S BExCBGL2-05 LED & Xenon Dual Beacon

E2S BExCBGL2-05 LED & Xenon Dual Beacon

The flameproof BExCBGL2-05 dual LED and Xenon beacons are suitable for Zone 1, 2, 21 & 22 applications. Approved to IECEx and ATEX standards.

The BExCBGL2-05D dual LED & 5 Joule Xenon beacons robust construction enables installation in the harshest of environments. The beacons may be connected from a single supply for simultaneous operation or from separate supplies for independent operation. 
The BEx range features enclosures manufactured from corrosion proof, marine grade copper free LM6 aluminium with a chromate and powder coat finish. All models have two M20 cable entries, large termination areas containing in & out terminals and an ingress protection of IP66/67.

General Features

Technical Specification

Ordering Codes :

BExCBGL205DPDC024AB1A1RRR

XENON Beacon  
Energy : 5 Joules (5Ws)
Flash Rate : 1Hz (60 fpm)
Peak Candela : 39,463 cd - 1Hz flash
TR-CU Ex EAC Certificate : RU C-GB.AA71.B.00109
Eff Intensity Cd : 120 cd - 1Hz flash
Peak Candela : 39,463 cd* x2 - measured ref. to I.E.S.
Eff Intensity Cd : 120 cd* x2 - measured ref. to I.E.S.
Lens Color : Amber, Blue, Clear, Green, Magenta, Red & Yellow
LED Beacon  
Souce : Array of 4 x High Power Cree® LED's
Eff Intensity Cd : 87 cd - High Power Steady
Eff Intensity Cd : 160 cd - 1Hz flash
Voltage DC : 12vdc; 24vdc; 48vdc
Voltage AC : 115V ac; 230V ac
Ingress Protection : IP66/67
Enclosure Material : Marine grade copper free LM6 Aluminium
Enclosure Finish : Chromate & powder coated finish - anti-corrosion.
Color : RAL3000 Red (others available on request)
Cable Entries : Dual M20 ISO (one stopping plug inc)
Terminals : 0.5 - 2.5mm² (20-14 AWG)
Enclosure Volume : <2 litres
Line Monitor : Blocking diode included , EOL Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor or diode (DC versions) can be fitted
Tube Life : Emissions are reduced to 70% after 8 million flashes
LED Life : 60,000 hours
Grounding Stud : M5
Temperature Range : -50° to +70°C (-58°F to +158°F)
Relative Humidity : 95% - Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist
Weight : DC: 4.00kg/8.8Ibs AC: 4.35kg/9.57Ibs
Approval :
  • IECEx KEM 10.0024X 
    IEC 60079-0 : 2011 
    IEC 60079-1 : 2007-4 
    IEC 60079-31 : 2013

  • ATEX KEMA 01ATEX2222X 
    EN 60079-0 : 2012 + A11 
    EN 60079-1 : 2007 
    EN 60079-31 : 2014

  • TR-CU Ex EAC certificate: RU C-GB.AA71.B.0010

Coding :
  • II 2G Ex d IIB T5 Gb Ta. -50°C to +40°C
  • II 2G Ex d IIB T4 Gb Ta. -50°C to +70°C
  • II 2D Ex tb IIIC T95°C Db Ta. -50°C to +40°C
  • II 2D Ex tb IIIC T110°C Db Ta. -50°C to +55°C
  • II 2D Ex tb IIIC T125°C Db Ta. -50°C to +70°C
WhatsApp Contact