E2S BExCBG05-05 Explosion Proof Dual Xenon Beacon

E2S BExCBG05-05 Explosion Proof Dual Xenon Beacon

The flameproof BExCBG05-05 dual Xenon beacons are suitable for Zone 1, 2, 21 & 22 applications. Approved to IECEx, ATEX and Ex EAC standards.

The BExCBG05-05D dual 5 Joule beacons robust construction enables installation in the harshest of environments. The beacons may be connected from a single supply for simultaneous operation or from separate supplies for independent operation. Additional features include automatic synchronisation on multi-beacon systems and stainless steel guard and mounting bracket as standard. 
The BEx range features enclosures manufactured from corrosion proof, marine grade copper free LM6 aluminium with a chromate and powder coat finish. All models have two M20 cable entries, large termination areas containing in & out terminals and an ingress protection of IP66/67.

General Features

Technical Specification

Ordering Codes :

BEXCBG0505DDC024-AB1A1RRR

Energy : 5 Joules x 2 (5Ws)
Flash Rate : 1Hz (60 fpm)
Peak Candela : 500,000 cd x2 - calculated from energy (J)
TR-CU Ex EAC Certificate : RU C-GB.AA71.B.00109
Eff Intensity Cd : 250 cd x2 - calculated from energy (J)
Peak Candela : 39,463 cd* x2 - measured ref. to I.E.S.
Eff Intensity Cd : 120 cd* x2 - measured ref. to I.E.S.
Lens Color : Amber, Blue, Clear, Green, Magenta, Red & Yellow
Voltage DC : 12vdc; 24vdc; 48vdc
Voltage AC : 115V ac; 230V ac
Ingress Protection : IP66/67
Enclosure Material : Marine grade copper free LM6 Aluminium
Enclosure Finish : Chromate & powder coated finish - anti-corrosion.
Color : RAL3000 Red (others available on request)
Cable Entries : Dual M20 ISO (one stopping plug inc)
Terminals : 0.5 - 2.5mm² (20-14 AWG)
Enclosure Volume : <2 litres
Line Monitor : Blocking diode included , EOL Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor or diode (DC versions) can be fitted
Tube Life : Emissions are reduced to 70% after 8 million flashes
Grounding Stud : M5
Temperature Range : -50° to +70°C (-58°F to +158°F)
Relative Humidity : 95% - Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist
Weight : DC: 4.00kg/8.8Ibs AC: 4.35kg/9.57Ibs
Approval :

IECEx KEM 10.0024X 
IEC 60079-0 : 2011 
IEC 60079-1 : 2007-4 
IEC 60079-31 : 2013

ATEX KEMA 00ATEX2222X 
EN 60079-0 : 2012 + A11 
EN 60079-1 : 2007 
EN 60079-31 : 2014

Coding :
  • II 2G Ex d IIB T4 Gb Ta. -50°C to +70°C
  • II 2D Ex tb IIIC T115°C Db Ta. -50°C to +55°C
  • II 2D Ex tb IIIC T130°C Db Ta. -50°C to +70°C
WhatsApp Contact