E2S BExBG21 Explosion Proof Xenon Beacon

E2S BExBG21 Explosion Proof Xenon Beacon

The flameproof BExBG21 Xenon beacons are suitable for Zone 1, 2, 21 & 22 applications. Approved to IECEx, ATEX, Ex EAC and INMETRO standards.

The BExBG21 21 Joule beacons robust construction enables installation in the harshest of environments. The BExBG21 has three distinct user selectable flash patterns and for units with DC operating voltages a second stage flash pattern can be selected remotely. Additional features include a stainless steel guard and stainless steel mounting bracket as standard. 
The BEx range features enclosures manufactured from corrosion proof, marine grade copper free LM6 aluminium with a chromate and powder coat finish. All models have two M20 cable entries, large termination areas containing in & out terminals and an ingress protection of IP66/67.

General Features

Technical Specification

Ordering Codes :

BEXBG10DPDC024AB1A1RR

Energy : 10 Joules (10Ws)
Flash Rate : 1Hz (60 fpm)
Peak Candela : 87,590 cd* - measured ref. to I.E.S.
Safety Integrity Level : Safety-integrity level: SIL2
Inmetro Certificate : 10-IEx-0010
Eff Intensity Cd : 250 cd - calculated from energy (J)
Peak Candela : 1,000,000 cd - calculated from energy (J)
Eff Intensity Cd : 120 cd* - measured ref. to I.E.S.
Lens Color : Amber, Blue, Clear, Green, Magenta, Red & Yellow
Voltage DC : 12vdc; 24vdc; 48vdc
Voltage AC : 115V ac; 230V ac
Ingress Protection : BG10D : IP66/67 BG10E : IP66
Enclosure Material : Marine grade copper free LM6 Aluminium
Enclosure Finish : Chromate & powder coated finish - anti-corrosion.
Color : RAL3000 Red (others available on request)
Cable Entries : Dual M20 ISO (one stopping plug inc)
Terminals : 0.5 - 2.5mm² (20-14 AWG)
Enclosure Volume : <2 litres
Line Monitor : Blocking diode included , EOL Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor or diode (DC versions) can be fitted
Tube Life : Emissions are reduced to 70% after 5 million flashes
Grounding Stud : M5
Temperature Range : -50° to +70°C (-58°F to +158°F)
Relative Humidity : 95% - Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist
Weight : DC: 2.45kg/5.39Ibs AC: 2.75kg/6.05Ibs
Option S1 : SIL2 Compliant versions - contact E2S for technical info.
Coding :
  • II 2G Ex d IIC T5 Gb Ta. -50°C to +45°C
  • II 2G Ex d IIC T4 Gb Ta. -50°C to +70°C
  • II 2D Ex tb IIIC T90°C Db Ta. -50°C to +40°C
  • II 2D Ex tb IIIC T105°C Db Ta. -50°C to +55°C
  • II 2D Ex tb IIIC T120°C Db Ta. -50°C to +70°C
WhatsApp Contact