E2S BExBG05 Explosion Proof Xenon Beacon

E2S BExBG05 Explosion Proof Xenon Beacon

The flameproof BExBG05 Xenon beacons are suitable for Zone 1, 2, 21 & 22 applications. Approved to IECEx, ATEX, Ex EAC and INMETRO standards.

The BExBG05 5 Joule beacons robust construction enables installation in the harshest of environments. Additional features include automatic synchronisation on multi-beacon systems and stainless steel guard and mounting bracket as standard. 
The BEx range features enclosures manufactured from corrosion proof, marine grade copper free LM6 aluminium with a chromate and powder coat finish. All models have two M20 cable entries, large termination areas containing in & out terminals and an ingress protection of IP66/67.

General Features

Technical Specification

Ordering Codes :

BEXBGL2DPDC024AB1A1RR

Energy : 5 Joules (5Ws)
Flash Rate : 1Hz (60 fpm)
Peak Candela : 500,000 cd - calculated from energy (J)
Eff Intensity Cd : 250 cd - calculated from energy (J)
Peak Candela : 39,463 cd* - measured ref. to I.E.S.
Eff Intensity Cd : 120 cd* - measured ref. to I.E.S.
Lens Color : Amber, Blue, Clear, Green, Magenta, Red & Yellow
Voltage DC : 12vdc; 24vdc; 48vdc
Voltage AC : 115V ac; 230V ac
Ingress Protection : BG05D : IP66/67 BG05E : IP66
Enclosure Material : Marine grade copper free LM6 Aluminium
Enclosure Finish : Chromate & powder coated finish - anti-corrosion.
Color : RAL3000 Red (others available on request)
Cable Entries : Dual M20 ISO (one stopping plug inc)
Terminals : 0.5 - 2.5mm² (20-14 AWG)
Enclosure Volume : <2 litres
Line Monitor : Blocking diode included , EOL Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor or diode (DC versions) can be fitted
Tube Life : Emissions are reduced to 70% after 5 million flashes
Grounding Stud : M5
Temperature Range : -50° to +70°C (-58°F to +158°F)
Relative Humidity : 95% - Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist
Weight : DC: 2.45kg/5.39Ibs AC: 2.75kg/6.05Ibs
Option S1 : SIL2 Compliant versions - contact E2S for technical info.
Coding :
  • II 2G Ex d IIC T5 Gb Ta. -50°C to +45°C
  • II 2G Ex d IIC T4 Gb Ta. -50°C to +70°C
  • II 2D Ex tb IIIC T90°C Db Ta. -50°C to +40°C
  • II 2D Ex tb IIIC T105°C Db Ta. -50°C to +55°C
  • II 2D Ex tb IIIC T120°C Db Ta. -50°C to +70°C