English
Furkan Engineering had been running for the world's security since 1992
 

 

Main Page > Fire Alarm Systems > Gas Detectors > LOREX Car Park Gas Detection Systems

 
LOREX Car Park Gas Detection Systems

LOREX Car Park Gas Detection Systems
  • Both underground car park and car park gas detection is commonly fitted for personal protection and energy saving. If there is no exhaust gas pollution present then ventilation rates can be reduced to save energy. LOREX Car Park Gas Detection Systems provides very effective energy reduction solution and ensure the quality of air in car parks with detecting toxic gas.
  • Elements of LOREX Car Park Gas Detection Systems
  • - Addressable Control Panels ; For use with Car Park Control Panel to detect toxic and flammable gases in car parks. Control Panel can manage and monitor up to 256 detectors. With RS485 interface for ModBUS communication protocal monitoring and controlling up to 32 gas detectors provides a great advantege for cabling cost , extremely flexible and highly reliable, it allows monitoring gas detectors connected with addressable loops.Monitoring and programming can be managed easily with 2 X 8 LCD screen. The user does not need to introduce the connected detectors to the system with advanced DP-32 's software algorithm whole system can be controlled with 32 LEDs indicators, in this way to monitor the gas detector status on the line by gas type, measuring ranges levels and measuring types are automatically detected and displayed on the control panel.
  • - Gas Detectors ; CO ( Carbon Monoxide ) , NO2 ( Nitrogen Dioxide ) LPG ( Liquid Petroleum Gas )

Price : On Request - In Stock.  
   
Call Us for Bulk Orders
 
Technical Specifications

Order Code : LR-PPSKP - Addressable Gas Control Panel
Maximum Zone Capacity : 1-4
Maximum Detector Per Zone : 32
Supply Voltage : 230V AC
Battery Backup : 2x12V 4,3Ah
Maximum Cable Lenght : 1000mt. With 2x2x1,5mm LIHCH
Serial Communication : Rs485 ModeBUS
Display : 2 X 8 LCD
Alarm Threshold Level : 2 X NO/NC Relay Output per each zone
Fault Output : 1 X NO/NC Fault Output per each zone
Status Display : 5 Status LED per each zone
Fault Monitoring Each Detector : YES
IP Rating : IP54
Hazardous Area : Non Hazardous
Detector Compatibility : CO,NO2,LPG Detectors Can be Connected with same line
Storage Temperature : -25 / +60 °C
Operating Temperature : 0 / +55 °C
 
Carbon Monoxide Detector for Car Parks
Nitrogen Dioxide Detector for Car Parks
LPG Detector for Car Parks
Carbon Monoxide Detector for Car Parks
Nitrogen Dioxide Detector for Car Parks
LPG Detector for Car Parks
     
 
 